Click the screen to open the live demo of a real-size chocolate factory: utility, three generators, 600 kWp of solar, a battery and three fuel tanks, with the AI agent at work. No sign-up needed.
Explore the demo
cloud.automatix.com → Explore the live demo
Do you run generators, store diesel, buy power from the grid and maybe produce solar? Then energy is one of your biggest costs, and probably the least visible one. AutomatiX Cloud measures every source, every feeder and every litre of fuel, second by second. It shows it all on one live screen. Then its AI agent tells you where the money is going and what to do about it.

Your switchboard as a live single-line diagram: utility, generators, solar, batteries and every feeder. Switch to full-screen SCADA view for the control room.
Tank gauging to ±1 mm, volume corrected to 15 °C, water detection. Deliveries reconciled against the supplier's ticket. Theft and leaks flagged automatically.
Litres per kWh for each set, running hours, load, low-load running and frequency hunting. Know which generator burns too much before it costs you a rebuild.
Inverter-by-inverter production against expected yield. Battery state of charge and cycles. Soiling and faults detected from the data.
Power factor, harmonics, voltage excursions and phase imbalance on every meter. Capacitor-bank problems found before the utility penalty arrives.
Cost per kWh from each source, in real time. Cost centres with monthly budgets. Daily, monthly and yearly reports ready to print or export.
A guided tour on the live demo plant: overview, riser diagram, generators, fuel tanks, solar, power quality, reports, cost centres and the AI co-pilot, then the mobile app and the AX-RTU gateway.

Generators, compressed air and production feeders. Energy cost per line and per shift, and the losses nobody sees off-shift.
Back-up power that must never fail: generator health, fuel autonomy in days and the critical feeders, around the clock.
Many buildings and campuses in one portal. Budgets per faculty or building, and solar sized from your own load.
Tenant and common-area metering as cost centres. HVAC and lighting checked against opening hours.
Guest comfort without waste: kitchens, laundry and HVAC on one screen, and every diesel delivery reconciled.
Every branch in one portal. Cold storage, refrigeration and generators compared store by store.
The agentic AI reads every meter, generator, tank and inverter around the clock. It compares today with last week and last year, and with what the equipment should do. Then it turns the data into a short list of findings, ranked by how much money each one is worth, each with a clear recommended action.


Every truck is recorded: volume delivered and corrected to 15 °C, compared with the supplier's ticket. Short deliveries are flagged automatically.
A positive-displacement meter with air elimination and a printed ticket. Fill start and finish are logged from the field or the app.
Magnetostrictive probe: level to ±1 mm, temperature, water bottom, volume at 15 °C. Leak and theft detection day and night.
The same probe technology on the generator day tank. Transfers from the main tank are reconciled.
Differential fuel flow meter (supply − return, temperature compensated) plus the generator breaker meter: litres per kWh, load, hours, frequency.
Each PV inverter and battery is read over Modbus: production, expected yield, state of charge, faults. Hybrid inverters supported.
Energy, power, power factor, harmonics, voltage and current on the incomers, generator breakers and feeders.
Reads all devices over RS-485 and Modbus TCP. Sends data by Ethernet or 4G/5G and buffers it locally if the link is lost. The AX-RTU-300MAX adds edge AI.
Secure hosting, history, reports, alarms and the AI agent. Nothing to install or maintain on site.
Any web browser, the Windows and Mac apps, and the iOS and Android apps for phones and tablets. A full-screen SCADA view for the control room.
The RTU fits in the palm of your hand. Move it to another site, add a second plant or run a temporary audit in an afternoon.
Local buffer from 7 days up to 1 year: no data is lost when the internet drops. The data catches up automatically.
Start with fuel or a single incomer, then add feeders, solar and the AI later. Each step is just another device from the library.








One supplier for the complete IIoT solution: the edge gateway, the metering and the cloud. We select, supply, install and commission the field devices. Where you already have good meters, we connect those.

| RS-485 ports | 1 |
| Devices | up to 16 |
| Sampling | from 10 s |
| Uplink | Ethernet / 4G |
| Local buffer | 7 days |
| I/O | 4 DI / 2 DO |

| RS-485 ports | 2 |
| Devices | up to 64 |
| Sampling | from 5 s |
| Uplink | Dual Ethernet / 4G |
| Local buffer | 30 days |
| I/O | 8 DI / 4 DO / 2 AI |

Runs AI analytics at the edge, inside the plant, next to the meters, alongside the AI in the cloud.
| RS-485 ports | 4 + Modbus TCP gateway |
| Devices | up to 247 |
| Sampling | from 1 s |
| Uplink | Dual Ethernet / dual-SIM 4G/5G |
| Local buffer | 1 year |
| I/O | 16 DI / 8 DO / 4 AI · edge AI |
Class 0.2S–1 multifunction meters with harmonics, for incomers, generators and feeders.
Differential generator flow metering (supply − return, temperature compensated) and delivery meters with air elimination.
Magnetostrictive level probes: ±1 mm, multi-point temperature, water detection, volume at 15 °C.
Read directly over Modbus: per-inverter production, expected yield and alarms. Hybrid PV + battery supported.
State of charge, health, charge and discharge power, cycles. Behind a hybrid inverter or with their own meter.
Any make and size. The breaker meter and flow meter give litres per kWh. Controller alarms are wired to the RTU inputs.
The AutomatiX Diesel Monitoring System has run in factories, hospitals and malls since 2019, built with SIEMENS, MTS (Temposonics), TCS and Technoton devices. AutomatiX Cloud keeps that proven metering and adds the cloud, solar and storage, and AI.